IST-4075R Incubated Shaker(83L)


Tabletop type
Provides convenient internal observation environment

  • Optimized for use on bench top.
  • Convenient internal observation.
  • 120V, 60Hz

Ask For Quote

Structural Functional Features

  • Model optimized for use on experiment bench.
  • Up to 80°C, 500rpm enables setting of various experimental conditions.
  • Three operating modes: Temperature & Shaking, Temperature, or Shaking.
  • Door structure allows for easy sample removal/attach at the front.
  • Shaking structure with minimized vibration.
  • Four models according to refrigeration system and the size of the platform.

Use Convenience Features

  • Accurate rpm and temperature control through temperature auto-tuning / microprocessor PID and calibration.
  • Monitor via mobile app anytime, anywhere with LC Connected. (mobile monitoring system)
    (when purchased LC GreenBox)
  • Countdown timer (999 hours 59 minutes) of shaking operation.
  • Intuitive operation with color touch display.
  • High brightness / low-power LED illumination makes it easy to observe inside.
  • Spill drain port for internal cleanliness and easy maintenance.

Outstanding Safety

  • Over temperature limit function.
  • Soft start and stop shaking function.
  • Malfunction prevented by controller lock function.
  • Displays all information such as device operation and error occurrence.
  • Overcurrent protection device restricts operation when objects are caught inside the system and shaking is not possible.

Smart Self-diagnosis

  • Real-time self-diagnostics to check equipment for abnormal conditions.
  • Alarm is generated by monitoring difference between actual rpm/temperature and set rpm/temperature.
  • Automatic rpm adjustment when device instability occurs.
    (high rpm, overload, weight imbalance, etc.)
  • Detects abnormal conditions relating to the platform on which the sample is placed and stops the operation.
  • Automatic restart as it was operated after power recovery.

 

 

SKU: AAH23765U Category:
Temperature
Range (℃ / ℉) Amb. -15 (Min. 15) to 80 / Amb. -27 (Min. 27) to 176
Fluctuation at 37℃ (±℃ / ℉) in flask 0.1 / 0.18
Variation at 37℃ (±℃ / ℉) in flask 0.5 / 0.90
Refrigerator (Hp) 1/6
Shaking system
Motion type Orbital
Speed range (rpm) 20 to 500
Max. speed per permissible load (rpm) 500 (max. 14 kg / 30.9 Ibs)
400 (max. 21 kg / 46.3 Ibs)
Amplitude size (mm / inch, dia.) 19.1 / 0.75
Speed stability2) (rpm, %) ±1
Timer (count-down) 999 hr 59 min.
Dimension
Chamber volume (L / cu ft) 83 / 2.9
Platform (W x D, mm / inch) 450 x 450 / 17.7 x 17.7
Interior (W x D x H, mm / inch) 510 x 510 x 320 / 20.1 x 20.1 x 12.6
Exterior (W x D x H, mm / inch) 540 x 890 x 510 / 21.3 x 35 x 20.1
Net weight (Kg / lbs) 90 / 198.4
Electrical requirements (120V, A) 60Hz, 10.1
Cat. No. AAH23765U

1) The temperature control range of the ISS-7100 and ISS-7200 models are from 10°C above the ambient temperature of the equipment. (15°C to 40°C) to 80°C The temperature control range of the ISS-7100R and ISS-7200R models are from 20°C below the ambient temperature (18°C to 35°C) of the device to 80°C. (However, the lowest control temperature is 4°C)
2) Actual rpm allowable error for set rpm is 1rpm if setting is less than 100rpm, ±1% if setting is higher than 100rpm.