OF4-15V Advanced Forced Convection Oven (147L)

Availability:

In stock (can be backordered)


Superb air dispersion and uniform temperature distribution.

  • 120V, 60Hz, US Plug

$3,779.00

In stock (can be backordered)

Wide touch-screen controller that provides the device information intuitively

  • 5-Inch TFT touch controller that enables intuitive control of the device.
  • Real-time graphs that allow users to view events and alarms at a glance so that the test progress can be easily and intuitively monitored.
  • Auto 3 temperature recommendation based on operating history without any recording or storage.
  • Wait on/Wait off timer setting allowing efficient test schedule management.
  • Ramping rates (℃/min) flexibly adjustable for each test performed.
Easy and intuitive program setting interface
Program setting can be flexibly adjusted according to each test requirement

 

 

Structural and functional features for improved user convenience

  • Opti-flow™, a function to flexibly adjust the fan speed
    according to the specimen type and test conditions.
  • Stacking Kit (optional) ensuring the safe fitting of one unit
    to another, thus doubling the amount of work done in a given area for improved space efficiency.
  • Hands-free™ door system to allow users to easily open
    the door while carrying samples with both hands.
Fan speed can be adjusted manually according

 

 

Real-time monitoring to check status of device

  • BMS communication port that helps monitor the device temperature on the building management system, enabling quick response in case of abnormality. (option)
  • Monitor and control via mobile app anytime, anywhere with LC Connected. (mobile monitoring system) (option)
BMS communication port that helps enable quick response through continuous monitoring (option)
Real-time monitoring and control via mobile (option)

 

 

Convenient checking for the test progress and data

  • RS-232/USB port and compatible software provided to enable easy device control and data management using PC.
  • Test data is automatically saved and easily downloaded via USB;
    easy to edit and use. (in CSV format)
  • 36 latest events, such as errors and door opened or closed, automatically recorded, helping user obtain feedback on experimental results.
Data storage using USB ports
Up to 36 latest events automatically recorded

 

 

Reliable temperature control performance based on stable control mechanisms

  • Wide temperature range of up to 250℃.
  • Three-point temperature calibration that ensures high temperature accuracy over a wide temperature range.
  • Ramping rates (℃/min) flexibly adjustable for each test performed.
  • Excellent temperature distribution through the formation of optimal airflow for uniform heat transfer.
    (±1.9℃ or below at 100℃)
Three-point temperature calibration that ensures precise temperature control
Ramping rates adjusted for each test performed

 

SKU: AAH12746U Category:
Model Solid door (without window) OF4-15V
Window door OF4-15VW
Chamber volume (L/cu ft) 147/5.19
Temperature 1) Range (℃/℉) Amb. + 10~250 / Amb. + 18 ~ 482
Fluctuation at 100℃ (±℃/±℉) 0.3/0.54
Variation at 100℃ (±℃/±℉) 1.5/2.70
Heating time to 100℃ (min) 15
Recovery time at 100℃ (min) 4
Control Panel 5inch TFT Color LCD
Communication interface USB, RS-232, BMS
Function Recently event record 36ea
Fan speed adjustable Three-step wind speed settings
Recommended temperature Three frequently used temperature settings suggested
Graph Available checking the stored and real-time data as graphs
Data storage Save the test data in CSV format
Temp. ramping rate (℃/min. / ℉/min.) 0~5/0~9
Dimensions Interior (W x D x H, mm/inch) 550 x 376 x 710 /
21.65 x 14.80 x 27.95
Exterior (W x D x H, mm/inch) 728 x 704 x 914 /
28.66 X 27.72 X 35.98
Net weight (kg/lbs) 73/160.9
Shelves Quantity of shelves (Standard/max.) 2/9
Max. Load per shelf (kg/lbs) 30/66.1
Number of Air change per hour at 100 ℃ 2) 11
Electrical requirements (120V, 60Hz, A) 12.3
Cat. No. Solid door (without window) AAH12746U
Window door AAH12846U
1) This data was measured when the fan speed was set to Step 5. If the fan speed is set to Step 1 or Step 3, the fluctuation and variation values will increase. (According to DIN 12880, before 2013)
2) This data was measured when the fan speed was set to Step 5. If the fan speed is set to Step 1 or Step 3, the number of air changes may decrease. (According to ASTM D 5374, reapproved 1999)